Your shopping cart

Heiland ANALYSER 500 - Analyzer for Ilford Sys. 500

sonstiges Heimlabor
Item Nr. 23304
Für weitere Info hier klicken. Artikel: Heiland ANALYSER 500 - Analyzer for Ilford Sys. 500
Drag mouse over image for larger view
  • Exposure, measuring and switching device for enlargers
  • For making black and white enlargements
  • Another variant of the AnalyserPro
  • Enables connection to the Ilford System 500
  • Operation only possible with Ilford control unit (available separately)

AnalyserPro
With this device you can make black and white enlargements with just a few test strips. The AnalyserPro can be combined with any enlarger and is suitable for exposing fixed-grade and multigrade paper.
This exposure, measuring and switching device for enlargers has a tone value indicator for predetermining gradation and exposure.
According to the motto: "Necessity is the mother of invention", the device was developed by photographers for photographers.
Some laboratory exposure meters display a paper gradation and exposure time after measuring the negative, which reproduce the shadows with maximum blackness and the high lights with paper white in the enlargement.
This is not always desirable, especially in portrait photography.
In contrast, the Analyzer Pro shows the tone values with which the measured negative areas are reproduced in the positive.
If you change the gradation and/or the exposure time using the keyboard, you can see the effects on the tonal value scale in the display.
The analyzer reduces the number of sample enlargements. You can see the expected result without using a single sheet of photographic paper.
The darkening of the wet print is also taken into account, as the display shows the tonal values of the dry enlargement.
The factory pre-calibration for several well-known multigrade papers can be optimally adjusted to your devices, materials and processing methods using a simple calibration method.

Analyzer 500
This version of the analyzer can be connected to the Ilford System 500.
The general functions and the light sensor correspond to the basic device. The two lamps in the Ilford lighting head are controlled directly. Operation without the Ilford control unit is NOT possible. This device is available on request.

Making an enlargement
In white light, measure at least 2 points, e.g. in the highlights and shadows of the projected negative.
Use the buttons to change the exposure time and gradation until the measuring points are displayed on the tone value scale in the desired range.
When using multigrade paper, set the gradation on the enlarger and then start the exposure time.

Features
The measuring device is calibrated in 2 passes (sensitivity and copy range) for all full gradation levels.
Up to eight measuring points of 5 mm diameter per negative.
15-gray scale.
After calibration, darkening during drying is also taken into account
Exposure times from 1 to 240 seconds adjustable in steps of 1/3, 1/4, 1/6 or 1/12 f-stops or also in 1/10 second steps.
Gradation adjustment in steps of 0.5 G.
The measuring range is 8 f-stops.
A foot switch is included in the scope of delivery.
Metronome function can be switched off every second.
Production of test strips.
Switching power of 750 watts for standard enlargers and cold light sources.

Dieser Artikel wird exklusiv für Sie bestellt.
602,94 sonstiges Heimlabor
incl. VAT /
14 days free return shipping.

Heiland ANALYSER 500 - Analyzer for Ilford Sys. 500

Short profile

  • Exposure, measuring and switching device for enlargers
  • For making black and white enlargements
  • Another variant of the AnalyserPro
  • Enables connection to the Ilford System 500
  • Operation only possible with Ilford control unit (available separately)

Product description for Heiland ANALYSER 500 - Analyzer for Ilford Sys. 500

AnalyserPro
With this device you can make black and white enlargements with just a few test strips. The AnalyserPro can be combined with any enlarger and is suitable for exposing fixed-grade and multigrade paper.
This exposure, measuring and switching device for enlargers has a tone value indicator for predetermining gradation and exposure.
According to the motto: "Necessity is the mother of invention", the device was developed by photographers for photographers.
Some laboratory exposure meters display a paper gradation and exposure time after measuring the negative, which reproduce the shadows with maximum blackness and the high lights with paper white in the enlargement.
This is not always desirable, especially in portrait photography.
In contrast, the Analyzer Pro shows the tone values with which the measured negative areas are reproduced in the positive.
If you change the gradation and/or the exposure time using the keyboard, you can see the effects on the tonal value scale in the display.
The analyzer reduces the number of sample enlargements. You can see the expected result without using a single sheet of photographic paper.
The darkening of the wet print is also taken into account, as the display shows the tonal values of the dry enlargement.
The factory pre-calibration for several well-known multigrade papers can be optimally adjusted to your devices, materials and processing methods using a simple calibration method.

Analyzer 500
This version of the analyzer can be connected to the Ilford System 500.
The general functions and the light sensor correspond to the basic device. The two lamps in the Ilford lighting head are controlled directly. Operation without the Ilford control unit is NOT possible. This device is available on request.

Making an enlargement
In white light, measure at least 2 points, e.g. in the highlights and shadows of the projected negative.
Use the buttons to change the exposure time and gradation until the measuring points are displayed on the tone value scale in the desired range.
When using multigrade paper, set the gradation on the enlarger and then start the exposure time.

Features
The measuring device is calibrated in 2 passes (sensitivity and copy range) for all full gradation levels.
Up to eight measuring points of 5 mm diameter per negative.
15-gray scale.
After calibration, darkening during drying is also taken into account
Exposure times from 1 to 240 seconds adjustable in steps of 1/3, 1/4, 1/6 or 1/12 f-stops or also in 1/10 second steps.
Gradation adjustment in steps of 0.5 G.
The measuring range is 8 f-stops.
A foot switch is included in the scope of delivery.
Metronome function can be switched off every second.
Production of test strips.
Switching power of 750 watts for standard enlargers and cold light sources.

Heiland ANALYSER 500 - Analyzer for Ilford Sys. 500

Lieferumfang
Im Lieferumfang
Die Ware wird mit dem Zubehör ausgeliefert, das vom Hersteller als zum Lieferumfang gehörend angegeben wird.
KAN
ANALYSER 500

Also interesting

Newsletter

Latest offers, exclusive benefits, news, events, info more

Subscribe now

The best cameras for beginners / novices

Photography is perhaps the most beautiful hobby! However, photography is certainly not one of the cheapest hobbies, and with this guide we want to give you an overview of which cameras are particularly well suited for starting this multi-faceted hobby.

Inform yourself now

First test of the Sony 16-35mm f2.8 GM2 compared to the 16-35 GM1

The new Sony 16-35mm GM2 is here and sets new standards! It is lighter, sharper and even more compact than its predecessor! Therefore, we'll show you the direct comparison of the two G-Master lenses and tell you whether an upgrade is worth it!

Read now

Camera Basics #12: Getting started with macro photography

Imaging small objects and details in a big way! That already describes macro photography very well! But what exactly could be a motif for this type of photography? Soap bubbles, insects, flowers, snowflakes and much more, that could include the shots as a motif.

learn more

The right binoculars for hunting

Finding an animal at a distance is not always easy, whether stalking, battue or driven hunt. A pair of binoculars as a perfect companion for hunting must require various criteria such as weather resistance under any condition, whether heavy rain or fog.

Read now

Things to know about deep discharge for camera batteries

Who has ever really dealt with camera batteries and the deep discharge. We have collected some information around the topic for you.

learn more

Guide for shooting stars photography

In this article we want to show you how you can easily photograph shooting stars. Use the current shooting star shower to take your first pictures.

Read now

Gift ideas for photographers

On this page you will find tips, suggestions and gift ideas about what your loved ones can finally be honestly happy